  1. Need Confirmation on Breaker Size and Wire Gauge for Heat Pump ...

    Jun 28, 2024 · Hi everyone, I'm getting ready to install a new heat pump and need some guidance on the correct breaker size and wire gauge for the setup. Here are the specs: Minimum Circuit …

  2. Help sizing circuit breaker feeding a motor via a VFD

    Jul 15, 2024 · The circuit breaker sizing for a motor with a vfd is essentially the same as for the motor without it, except where the vfd specifies a maximum scgf protection rating.

  3. Circuit Breaker Frame Size | Information by Electrical Professionals ...

    Jan 24, 2023 · What is meant by frame size for an instantaneous trip circuit breaker, and where does the 3 times 5 times 10 times for low medium high come from. Anyone know where I can read up on this. …

  4. AF and AT breaker notation - Mike Holt's Forum

    Nov 16, 2004 · Re: AF and AT breaker notation Frame rating and trip rating are often different, although often the same. Adjustable breakers certainly are an example. The frame rating is a maximum rating …

  5. What is the purpose of neutral disconnect in a circuit breaker?

    Nov 7, 2023 · I saw some circuit breakers that have a separate neutral disconnect. For example: What is that for? When do you need to disconnect the phases only? Why not use a circuit breaker that …

  6. MCP vs Circuit Breaker | Information by Electrical Professionals for ...

    Nov 17, 2015 · The MCP circuit breaker provides short-circuit protection, while the overloads provide the overload protection. So then this question arises: why aren't overloads used, let's say in 480v …

  7. 80% rule | Information by Electrical Professionals for Electrical ...

    Sep 23, 2020 · ALL circuit breakers are tested and listed to carry 100% of their rated load, but in "free air", meaning all sides of the breaker can dissipate heat (this becomes important later).

  8. kAIC Calculation | Information by Electrical Professionals for ...

    May 1, 2020 · Until now i cannot find how to calculate the kAIC rating for circuit breakers and main circuit breakers. Please give me some tips and advice. Thank you.

  9. Sizing circuit breakers for motors | Information by Electrical ...

    Sep 11, 2006 · I am a little confused as to how to correclty size a circuit breaker for protecting a motor. I am refering more specifically to continuous duty motors on a branch circuit from an MCC or or other …

  10. Is it okay to use two circuit breakers in parallel knowing it's okay ...

    Dec 22, 2024 · 1 Paralleling circuit breakers is not recommended. One breaker will trip at its rated current and as soon as that side of the circuit is open the other breaker will trip. There can never be a …